The hidden enemy – excess oil in the system
The first victims: variable-displacement compressors and electronic compressors.
In
a complete, proper job, professionals flush the system – and all the oil anywhere in it – with a flushing agent/fluid passed through the system, with the compressor, expansion valve and receiver drier removed.
Our compressor comes with a measured amount of oil, as recommended by the vehicle manufacturer, which accounts for what the compressor needs plus 20% for the oil that constantly circulates with the refrigerant in the system.
The problem – for example after an accident: a compressor broken in a collision, or "a clean system doesn't need flushing",
or "flushing" with air (heaven forbid – because of the moisture) or with nitrogen, which doesn't dissolve and blow out the oil – just as you can't wash with air instead of soap – so most of the oil stays in.
As mentioned, the compressor comes with the correct amount of oil + the old oil already in the system = excess oil.
A conventional compressor will meet resistance until it stalls; with a variable-displacement or electronic compressor, the control won't regulate and the compressor won't run (the symptom is described in detail in question 1: the gauges read the same, 85–95 PSI, with no pressure build-up and no cooling – which is just the static refrigerant charge).
Familiar problems can sometimes have unfamiliar causes. Every time, it's worth checking more than one possibility, and consulting and sharing as much as you can.
Everything above comes from our customers' experience in the field. It does not replace technical instructions, regulations or common sense.
We recommend treating all of the above as an additional perspective on a familiar problem. It is not an instruction to act against standard technical procedures, and it does not replace common sense or troubleshooting other problems that may exist in the system.