Common mistakes when installing a variable-displacement compressor

You've finished the installation and both gauges read the same:

PSI

*85–95, with no pressure build-up and no cooling.

You charged 750 grams of refrigerant, for example, replaced the expansion valve and receiver drier, and the compressor won't engage – and there's an obvious suspect: the compressor…

Well, contrary to what the car manufacturers recommend – in our hot, non-European climate, and from our customers' experience – it's better to charge 650 grams through the high and low sides together. The important part: don't switch the compressor on right away. Wait for the pressures to equalize for at least half an hour (that's 30 minutes…), then run it at idle and hope it wasn't damaged by an incorrect first start-up.

If it still doesn't build pressure, slowly add 50 grams of refrigerant.

As soon as the compressor engages, disconnect the manifold gauges

and don't add refrigerant or oil.

Another reason the compressor won't run – see question 5 on this page, about excess oil in the system.

*More precisely, about 80–95, because of the small minimum angle of the swash plate, which lets the compressor start working and keeps it lubricated even when it isn't engaged.

Familiar problems can sometimes have unfamiliar causes. Every time, it's worth checking more than one possibility, and consulting and sharing as much as you can.

Everything above comes from our customers' experience in the field. It does not replace technical instructions, regulations or common sense.

We recommend treating all of the above as an additional perspective on a familiar problem. It is not an instruction to act against standard technical procedures, and it does not replace common sense or troubleshooting other problems that may exist in the system.